{"id":1128,"date":"2024-03-26T16:50:21","date_gmt":"2024-03-26T11:20:21","guid":{"rendered":"https:\/\/vipulac.in\/blog\/?p=1128"},"modified":"2024-03-26T16:52:48","modified_gmt":"2024-03-26T11:22:48","slug":"what-is-ahu-and-tfa","status":"publish","type":"post","link":"https:\/\/vipulac.in\/blog\/what-is-ahu-and-tfa\/","title":{"rendered":"What is AHU and TFA?"},"content":{"rendered":"<p data-sourcepos=\"1:1-1:104\">AHU and TFA are both acronyms used in HVAC systems for buildings, but they handle air in different ways:<\/p>\n<h3><strong>Air Handling Unit (AHU):<\/strong><\/h3>\n<p>An AHU is a workhorse in an HVAC system, conditioning and distributing air throughout a building. Imagine a large metal box that treats incoming outdoor air before sending it on its way. Here&#8217;s a breakdown of how an AHU typically functions:<\/p>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul data-sourcepos=\"4:5-8:0\">\n<li data-sourcepos=\"4:5-4:54\"><strong>Intake:<\/strong>\u00a0Outdoor air gets drawn into the AHU.<\/li>\n<li data-sourcepos=\"5:5-5:80\"><strong>Filtration:<\/strong>\u00a0Filters remove dust, pollen, and other unwanted particles.<\/li>\n<li data-sourcepos=\"6:5-6:178\"><strong>Conditioning:<\/strong>\u00a0The air is heated or cooled using coils and heating\/cooling elements to reach the desired temperature. Additionally, some AHUs can adjust humidity levels.<\/li>\n<li data-sourcepos=\"7:5-8:0\"><strong>Distribution:<\/strong>\u00a0The conditioned air is then distributed through a network of ducts to various zones or rooms in the building.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<div class=\"attachment-container search-images\">\n<div class=\"image-container hide-from-message-actions ng-star-inserted\"><\/div>\n<\/div>\n<div class=\"container\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-1101 aligncenter\" src=\"https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2024\/03\/The-structure-diagram-of-the-air-handling-unit-AHU-in-the-laboratory-1-1-300x191.png\" alt=\"\" width=\"300\" height=\"191\" srcset=\"https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2024\/03\/The-structure-diagram-of-the-air-handling-unit-AHU-in-the-laboratory-1-1-300x191.png 300w, https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2024\/03\/The-structure-diagram-of-the-air-handling-unit-AHU-in-the-laboratory-1-1-600x381.png 600w, https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2024\/03\/The-structure-diagram-of-the-air-handling-unit-AHU-in-the-laboratory-1-1-768x488.png 768w, https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2024\/03\/The-structure-diagram-of-the-air-handling-unit-AHU-in-the-laboratory-1-1.png 826w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/div>\n<div>\n<h3><strong>Treated Fresh Air (TFA) Unit:<\/strong><\/h3>\n<p>A TFA is a specific type of AHU designed to provide a building with 100% fresh outdoor air. Unlike AHUs, TFAs don&#8217;t mix any recirculated return air from the building with the incoming fresh air stream. This makes them ideal for applications requiring a constant supply of clean, fresh air, such as hospitals, clean rooms, and laboratories.<\/p>\n<\/div>\n<p><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-1129 aligncenter\" src=\"https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2024\/03\/TFA-Blog-1024x538-1-300x158.png\" alt=\"\" width=\"355\" height=\"187\" srcset=\"https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2024\/03\/TFA-Blog-1024x538-1-300x158.png 300w, https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2024\/03\/TFA-Blog-1024x538-1-600x315.png 600w, https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2024\/03\/TFA-Blog-1024x538-1-768x404.png 768w, https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2024\/03\/TFA-Blog-1024x538-1.png 1024w\" sizes=\"auto, (max-width: 355px) 100vw, 355px\" \/><\/p>\n<p>&nbsp;<\/p>\n<div>\n<p data-sourcepos=\"17:1-17:69\">Here&#8217;s a table summarizing the key differences between AHUs and TFAs:<\/p>\n<div class=\"horizontal-scroll-wrapper\">\n<div class=\"table-block-component\">\n<div class=\"table-block\">\n<div><\/div>\n<div class=\"table-content\">\n<table data-sourcepos=\"19:1-23:106\">\n<tbody>\n<tr data-sourcepos=\"19:1-19:23\">\n<th data-sourcepos=\"19:1-19:9\">Feature<\/th>\n<th data-sourcepos=\"19:11-19:15\">AHU<\/th>\n<th data-sourcepos=\"19:17-19:21\">TFA<\/th>\n<\/tr>\n<tr data-sourcepos=\"21:1-21:110\">\n<td data-sourcepos=\"21:1-21:14\"><strong>Function<\/strong><\/td>\n<td data-sourcepos=\"21:16-21:74\">Conditions and distributes mixed (outdoor and return) air<\/td>\n<td data-sourcepos=\"21:76-21:108\">Provides 100% fresh outdoor air<\/td>\n<\/tr>\n<tr data-sourcepos=\"22:1-22:65\">\n<td data-sourcepos=\"22:1-22:22\"><strong>Fresh Air Intake<\/strong><\/td>\n<td data-sourcepos=\"22:24-22:46\">Mixed with return air<\/td>\n<td data-sourcepos=\"22:48-22:63\">100% fresh air<\/td>\n<\/tr>\n<tr data-sourcepos=\"23:1-23:106\">\n<td data-sourcepos=\"23:1-23:18\"><strong>Applications<\/strong><\/td>\n<td data-sourcepos=\"23:20-23:65\">General commercial and residential buildings<\/td>\n<td data-sourcepos=\"23:67-23:104\">Hospitals, clean rooms, laboratories<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p data-sourcepos=\"25:1-25:265\">In essence, AHUs offer more flexibility in handling mixed air streams, while TFAs provide a dedicated stream of conditioned fresh air. The choice between an AHU and a TFA depends on the specific needs of the building and the required level of fresh air ventilation.<\/p>\n<\/div>\n<h4 style=\"text-align: center;\"><strong>Looking to install a commercial <a href=\"https:\/\/vipulhvacsolution.in\/\">HVAC System or Duct work<\/a> in your Business Area?\u00a0<\/strong><\/h4>\n<p style=\"text-align: center;\">Contact\u00a0<a href=\"https:\/\/vipulac.in\/\"><strong>Vipul Ac<\/strong><\/a>\u00a0to learn about our HVAC Service<\/p>\n<p style=\"text-align: center;\">Call\u00a0<strong>+91\u00a0<span style=\"color: #800000;\">8000092000<\/span><\/strong>\u00a0Today.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>AHU and TFA are both acronyms used in HVAC systems for buildings, but they handle air in different ways: Air Handling Unit (AHU): An AHU is a workhorse in an HVAC system, conditioning and distributing air throughout a building. Imagine a large metal box that treats incoming outdoor air before sending it on its way. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"footnotes":""},"categories":[2],"tags":[],"class_list":["post-1128","post","type-post","status-publish","format-standard","hentry","category-hvac-system"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>What is AHU and TFA? - The Complete HVAC Solutions | Call now +91 8000392000<\/title>\n<meta name=\"description\" content=\"What is AHU and TFA? AHU and TFA are both acronyms used in HVAC systems for buildings, but they handle air in different ways.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/vipulac.in\/blog\/what-is-ahu-and-tfa\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What is AHU and TFA? - The Complete HVAC Solutions | Call now +91 8000392000\" \/>\n<meta property=\"og:description\" content=\"What is AHU and TFA? AHU and TFA are both acronyms used in HVAC systems for buildings, but they handle air in different ways.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/vipulac.in\/blog\/what-is-ahu-and-tfa\/\" \/>\n<meta property=\"og:site_name\" content=\"The Complete HVAC Solutions | Call now +91 8000392000\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/VipulNeverSleep\/\" \/>\n<meta property=\"article:published_time\" content=\"2024-03-26T11:20:21+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-03-26T11:22:48+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2024\/03\/The-structure-diagram-of-the-air-handling-unit-AHU-in-the-laboratory-1-1-300x191.png\" \/>\n<meta name=\"author\" content=\"bhaveshk\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@VipulNeverSleep\" \/>\n<meta name=\"twitter:site\" content=\"@VipulNeverSleep\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"bhaveshk\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/what-is-ahu-and-tfa\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/what-is-ahu-and-tfa\\\/\"},\"author\":{\"name\":\"bhaveshk\",\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/#\\\/schema\\\/person\\\/f81ca3288761d151243f2694fedd3e38\"},\"headline\":\"What is AHU and TFA?\",\"datePublished\":\"2024-03-26T11:20:21+00:00\",\"dateModified\":\"2024-03-26T11:22:48+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/what-is-ahu-and-tfa\\\/\"},\"wordCount\":312,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/what-is-ahu-and-tfa\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/03\\\/The-structure-diagram-of-the-air-handling-unit-AHU-in-the-laboratory-1-1-300x191.png\",\"articleSection\":[\"HVAC System\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/vipulac.in\\\/blog\\\/what-is-ahu-and-tfa\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/what-is-ahu-and-tfa\\\/\",\"url\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/what-is-ahu-and-tfa\\\/\",\"name\":\"What is AHU and TFA? - The Complete HVAC Solutions | Call now +91 8000392000\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/what-is-ahu-and-tfa\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/what-is-ahu-and-tfa\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/03\\\/The-structure-diagram-of-the-air-handling-unit-AHU-in-the-laboratory-1-1-300x191.png\",\"datePublished\":\"2024-03-26T11:20:21+00:00\",\"dateModified\":\"2024-03-26T11:22:48+00:00\",\"description\":\"What is AHU and TFA? AHU and TFA are both acronyms used in HVAC systems for buildings, but they handle air in different ways.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/what-is-ahu-and-tfa\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/vipulac.in\\\/blog\\\/what-is-ahu-and-tfa\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/what-is-ahu-and-tfa\\\/#primaryimage\",\"url\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/03\\\/The-structure-diagram-of-the-air-handling-unit-AHU-in-the-laboratory-1-1.png\",\"contentUrl\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/03\\\/The-structure-diagram-of-the-air-handling-unit-AHU-in-the-laboratory-1-1.png\",\"width\":826,\"height\":525},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/what-is-ahu-and-tfa\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What is AHU and TFA?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/\",\"name\":\"The Complete HVAC Solutions | Call now +91 8000392000\",\"description\":\"The Complete HVAC &amp; VRF Solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/#organization\",\"name\":\"Vipul AC\",\"alternateName\":\"Vipul HVAC Solution PvT. Ltd.\",\"url\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/cropped-vipul_ac_logo-1.png\",\"contentUrl\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/cropped-vipul_ac_logo-1.png\",\"width\":240,\"height\":72,\"caption\":\"Vipul AC\"},\"image\":{\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/VipulNeverSleep\\\/\",\"https:\\\/\\\/x.com\\\/VipulNeverSleep\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/vipulac\\\/\",\"https:\\\/\\\/www.instagram.com\\\/vipulaircondition\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/#\\\/schema\\\/person\\\/f81ca3288761d151243f2694fedd3e38\",\"name\":\"bhaveshk\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/5a5186bf62b0fb1f890be660179375d8bba84123066154ffb79e5a96bb20c75a?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/5a5186bf62b0fb1f890be660179375d8bba84123066154ffb79e5a96bb20c75a?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/5a5186bf62b0fb1f890be660179375d8bba84123066154ffb79e5a96bb20c75a?s=96&d=mm&r=g\",\"caption\":\"bhaveshk\"},\"sameAs\":[\"https:\\\/\\\/vipulac.in\\\/blog\"],\"url\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/author\\\/bhaveshk\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"What is AHU and TFA? - The Complete HVAC Solutions | Call now +91 8000392000","description":"What is AHU and TFA? AHU and TFA are both acronyms used in HVAC systems for buildings, but they handle air in different ways.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/vipulac.in\/blog\/what-is-ahu-and-tfa\/","og_locale":"en_US","og_type":"article","og_title":"What is AHU and TFA? - The Complete HVAC Solutions | Call now +91 8000392000","og_description":"What is AHU and TFA? AHU and TFA are both acronyms used in HVAC systems for buildings, but they handle air in different ways.","og_url":"https:\/\/vipulac.in\/blog\/what-is-ahu-and-tfa\/","og_site_name":"The Complete HVAC Solutions | Call now +91 8000392000","article_publisher":"https:\/\/www.facebook.com\/VipulNeverSleep\/","article_published_time":"2024-03-26T11:20:21+00:00","article_modified_time":"2024-03-26T11:22:48+00:00","og_image":[{"url":"https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2024\/03\/The-structure-diagram-of-the-air-handling-unit-AHU-in-the-laboratory-1-1-300x191.png","type":"","width":"","height":""}],"author":"bhaveshk","twitter_card":"summary_large_image","twitter_creator":"@VipulNeverSleep","twitter_site":"@VipulNeverSleep","twitter_misc":{"Written by":"bhaveshk","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/vipulac.in\/blog\/what-is-ahu-and-tfa\/#article","isPartOf":{"@id":"https:\/\/vipulac.in\/blog\/what-is-ahu-and-tfa\/"},"author":{"name":"bhaveshk","@id":"https:\/\/vipulac.in\/blog\/#\/schema\/person\/f81ca3288761d151243f2694fedd3e38"},"headline":"What is AHU and TFA?","datePublished":"2024-03-26T11:20:21+00:00","dateModified":"2024-03-26T11:22:48+00:00","mainEntityOfPage":{"@id":"https:\/\/vipulac.in\/blog\/what-is-ahu-and-tfa\/"},"wordCount":312,"commentCount":0,"publisher":{"@id":"https:\/\/vipulac.in\/blog\/#organization"},"image":{"@id":"https:\/\/vipulac.in\/blog\/what-is-ahu-and-tfa\/#primaryimage"},"thumbnailUrl":"https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2024\/03\/The-structure-diagram-of-the-air-handling-unit-AHU-in-the-laboratory-1-1-300x191.png","articleSection":["HVAC System"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/vipulac.in\/blog\/what-is-ahu-and-tfa\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/vipulac.in\/blog\/what-is-ahu-and-tfa\/","url":"https:\/\/vipulac.in\/blog\/what-is-ahu-and-tfa\/","name":"What is AHU and TFA? - The Complete HVAC Solutions | Call now +91 8000392000","isPartOf":{"@id":"https:\/\/vipulac.in\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/vipulac.in\/blog\/what-is-ahu-and-tfa\/#primaryimage"},"image":{"@id":"https:\/\/vipulac.in\/blog\/what-is-ahu-and-tfa\/#primaryimage"},"thumbnailUrl":"https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2024\/03\/The-structure-diagram-of-the-air-handling-unit-AHU-in-the-laboratory-1-1-300x191.png","datePublished":"2024-03-26T11:20:21+00:00","dateModified":"2024-03-26T11:22:48+00:00","description":"What is AHU and TFA? AHU and TFA are both acronyms used in HVAC systems for buildings, but they handle air in different ways.","breadcrumb":{"@id":"https:\/\/vipulac.in\/blog\/what-is-ahu-and-tfa\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/vipulac.in\/blog\/what-is-ahu-and-tfa\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/vipulac.in\/blog\/what-is-ahu-and-tfa\/#primaryimage","url":"https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2024\/03\/The-structure-diagram-of-the-air-handling-unit-AHU-in-the-laboratory-1-1.png","contentUrl":"https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2024\/03\/The-structure-diagram-of-the-air-handling-unit-AHU-in-the-laboratory-1-1.png","width":826,"height":525},{"@type":"BreadcrumbList","@id":"https:\/\/vipulac.in\/blog\/what-is-ahu-and-tfa\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/vipulac.in\/blog\/"},{"@type":"ListItem","position":2,"name":"What is AHU and TFA?"}]},{"@type":"WebSite","@id":"https:\/\/vipulac.in\/blog\/#website","url":"https:\/\/vipulac.in\/blog\/","name":"The Complete HVAC Solutions | Call now +91 8000392000","description":"The Complete HVAC &amp; VRF Solutions","publisher":{"@id":"https:\/\/vipulac.in\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/vipulac.in\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/vipulac.in\/blog\/#organization","name":"Vipul AC","alternateName":"Vipul HVAC Solution PvT. Ltd.","url":"https:\/\/vipulac.in\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/vipulac.in\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2025\/10\/cropped-vipul_ac_logo-1.png","contentUrl":"https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2025\/10\/cropped-vipul_ac_logo-1.png","width":240,"height":72,"caption":"Vipul AC"},"image":{"@id":"https:\/\/vipulac.in\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/VipulNeverSleep\/","https:\/\/x.com\/VipulNeverSleep","https:\/\/www.linkedin.com\/in\/vipulac\/","https:\/\/www.instagram.com\/vipulaircondition\/"]},{"@type":"Person","@id":"https:\/\/vipulac.in\/blog\/#\/schema\/person\/f81ca3288761d151243f2694fedd3e38","name":"bhaveshk","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/5a5186bf62b0fb1f890be660179375d8bba84123066154ffb79e5a96bb20c75a?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/5a5186bf62b0fb1f890be660179375d8bba84123066154ffb79e5a96bb20c75a?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/5a5186bf62b0fb1f890be660179375d8bba84123066154ffb79e5a96bb20c75a?s=96&d=mm&r=g","caption":"bhaveshk"},"sameAs":["https:\/\/vipulac.in\/blog"],"url":"https:\/\/vipulac.in\/blog\/author\/bhaveshk\/"}]}},"_links":{"self":[{"href":"https:\/\/vipulac.in\/blog\/wp-json\/wp\/v2\/posts\/1128","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vipulac.in\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/vipulac.in\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/vipulac.in\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/vipulac.in\/blog\/wp-json\/wp\/v2\/comments?post=1128"}],"version-history":[{"count":1,"href":"https:\/\/vipulac.in\/blog\/wp-json\/wp\/v2\/posts\/1128\/revisions"}],"predecessor-version":[{"id":1130,"href":"https:\/\/vipulac.in\/blog\/wp-json\/wp\/v2\/posts\/1128\/revisions\/1130"}],"wp:attachment":[{"href":"https:\/\/vipulac.in\/blog\/wp-json\/wp\/v2\/media?parent=1128"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/vipulac.in\/blog\/wp-json\/wp\/v2\/categories?post=1128"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/vipulac.in\/blog\/wp-json\/wp\/v2\/tags?post=1128"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}