{"id":1839,"date":"2024-04-26T16:21:38","date_gmt":"2024-04-26T10:51:38","guid":{"rendered":"https:\/\/vipulac.in\/blog\/?p=1839"},"modified":"2024-04-26T17:02:12","modified_gmt":"2024-04-26T11:32:12","slug":"treated-fresh-air-unit-calculation","status":"publish","type":"post","link":"https:\/\/vipulac.in\/blog\/treated-fresh-air-unit-calculation\/","title":{"rendered":"Treated fresh air unit calculation"},"content":{"rendered":"<p data-sourcepos=\"1:1-1:327\">Treated fresh air unit calculation (TFA) involves several factors and can be complex. It&#8217;s generally recommended to consult with a qualified HVAC professional to ensure your unit is properly sized and meets your specific needs. However, here&#8217;s a breakdown of the key aspects involved in TFA calculations:<\/p>\n<h2 data-sourcepos=\"3:1-3:29\"><strong>1. Fresh Air Requirement:<\/strong><\/h2>\n<p data-sourcepos=\"5:1-5:129\">This is the core element. You need to determine the amount of fresh air required for your space. This depends on several factors:<\/p>\n<ul data-sourcepos=\"7:1-10:0\">\n<li data-sourcepos=\"7:1-7:238\"><strong>Building occupancy:<\/strong> The number of people using the space significantly impacts fresh air needs. Standards like ASHRAE 62.1 (Ventilation for Acceptable Indoor Air Quality) provide guidelines for minimum ventilation rates per person.<\/li>\n<li data-sourcepos=\"8:1-8:175\"><strong>Building type:<\/strong> Residential, commercial, and healthcare facilities have different fresh air requirements due to varying occupancy levels and potential indoor pollutants.<\/li>\n<li data-sourcepos=\"9:1-10:0\"><strong>Local building codes:<\/strong> Your local building code might have specific fresh air requirements that supersede general guidelines.<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-1858\" src=\"https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2024\/04\/455bmzgo-300x158.png\" alt=\"Treated fresh air unit calculation\" width=\"317\" height=\"167\" srcset=\"https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2024\/04\/455bmzgo-300x158.png 300w, https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2024\/04\/455bmzgo-600x315.png 600w, https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2024\/04\/455bmzgo-768x404.png 768w, https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2024\/04\/455bmzgo.png 1024w\" sizes=\"auto, (max-width: 317px) 100vw, 317px\" \/><\/p>\n<h2 data-sourcepos=\"11:1-11:24\"><strong>Calculation methods:<\/strong><\/h2>\n<p data-sourcepos=\"13:1-13:159\">There are multiple methods for calculating fresh air requirements, and an HVAC professional might use a combination of approaches. Some common methods include:<\/p>\n<ul data-sourcepos=\"15:1-18:0\">\n<li data-sourcepos=\"15:1-15:108\"><strong>Per person method:<\/strong> This method uses a fixed amount of fresh air per person (e.g., 15 CFM per person).<\/li>\n<li data-sourcepos=\"16:1-16:104\"><strong>Floor area method:<\/strong> This method assigns a specific fresh air volume per square foot of floor area.<\/li>\n<li data-sourcepos=\"17:1-18:0\"><strong>Zone calculation:<\/strong> This method takes into account the specific use of different zones within a building (e.g., higher requirements for break rooms compared to offices).<\/li>\n<\/ul>\n<h2 data-sourcepos=\"19:1-19:35\"><strong>2. Heat Load and Cooling Load:<\/strong><\/h2>\n<p data-sourcepos=\"21:1-21:135\">Once you have the fresh air requirement (CFM &#8211; Cubic Feet per Minute), you need to consider the impact on building heating and cooling:<\/p>\n<ul data-sourcepos=\"23:1-25:0\">\n<li data-sourcepos=\"23:1-23:224\"><strong>Heating Load:<\/strong> Fresh air entering from outside will likely be cooler than the desired indoor temperature. The TFA unit might need heating capability to raise the temperature of the incoming air before distributing it.<\/li>\n<li data-sourcepos=\"24:1-25:0\"><strong>Cooling Load:<\/strong> In hot climates, the TFA unit might need cooling capability to bring down the temperature of incoming fresh air before distribution.<\/li>\n<\/ul>\n<h3 data-sourcepos=\"26:1-26:24\"><strong>Calculation methods:<\/strong><\/h3>\n<p data-sourcepos=\"28:1-28:176\">These loads are typically calculated using engineering software or psychrometric charts that factor in outside air temperature, desired indoor temperature, and humidity levels.<\/p>\n<h2 data-sourcepos=\"30:1-30:34\"><strong>3. Unit Selection and Sizing:<\/strong><\/h2>\n<p data-sourcepos=\"32:1-32:146\">Based on the fresh air requirement and calculated heating\/cooling loads, an HVAC professional can select a TFA unit with the appropriate capacity:<\/p>\n<ul data-sourcepos=\"34:1-36:0\">\n<li data-sourcepos=\"34:1-34:96\"><strong>Airflow capacity:<\/strong> The unit&#8217;s CFM rating should meet or exceed your fresh air requirement.<\/li>\n<li data-sourcepos=\"35:1-36:0\"><strong>Heating\/Cooling capacity:<\/strong> The heating and cooling capacity of the TFA unit should be sufficient to handle the calculated loads.<\/li>\n<\/ul>\n<h3 data-sourcepos=\"37:1-37:30\"><strong>Additional Considerations:<\/strong><\/h3>\n<ul data-sourcepos=\"39:1-42:0\">\n<li data-sourcepos=\"39:1-39:148\"><strong>Filtration:<\/strong> The TFA unit should have adequate filtration to remove dust, pollen, and other airborne contaminants from the incoming fresh air.<\/li>\n<li data-sourcepos=\"40:1-40:126\"><strong>Noise levels:<\/strong> Consider the noise level generated by the TFA unit, especially if it&#8217;s located in a noise-sensitive area.<\/li>\n<li data-sourcepos=\"41:1-42:0\"><strong>Maintenance:<\/strong> Regular maintenance of filters and other components is crucial for optimal performance of the TFA unit.<\/li>\n<\/ul>\n<h3 data-sourcepos=\"43:1-43:14\"><strong>Resources:<\/strong><\/h3>\n<p data-sourcepos=\"45:1-45:168\">While the specific calculations are best left to professionals, here are some resources that can provide additional information on TFA units and fresh air requirements:<\/p>\n<ul data-sourcepos=\"47:1-49:0\">\n<li data-sourcepos=\"47:1-47:318\"><strong><span class=\"citation-0\">American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE):<\/span><\/strong> <a class=\"traceable-link\" href=\"https:\/\/www.ashrae.org\/technical-resources\/standards-and-guidelines\" target=\"_blank\" rel=\"noopener noreferrer\"><span class=\"citation-0 citation-1\">https:\/\/www.ashrae.org\/technical-resources\/standards-and-guidelines<\/span><\/a> (This website offers standards and guidelines like ASHRAE 62.1)<\/li>\n<li data-sourcepos=\"48:1-49:0\"><strong>Zeco Aircon &#8211; Treated Fresh Air Units (TFA):<\/strong> <a class=\"traceable-link\" href=\"https:\/\/zecoaircon.com\/product\/air-handling-unit\/\" target=\"_blank\" rel=\"noopener noreferrer\">https:\/\/zecoaircon.com\/product\/air-handling-unit\/<\/a> (This article provides a basic overview of TFA units)<\/li>\n<\/ul>\n<p data-sourcepos=\"50:1-50:176\">Remember, a qualified HVAC professional can perform the necessary calculations, select the most suitable TFA unit for your needs, and ensure proper installation and operation.<\/p>\n<h4 style=\"text-align: center;\"><strong>Looking to install a commercial\u00a0<a href=\"https:\/\/vipulhvacsolution.in\/\">HVAC System or Duct work<\/a>\u00a0in your Business Area?\u00a0<\/strong><\/h4>\n<p style=\"text-align: center;\">Contact qualified HVAC professional\u00a0<a href=\"https:\/\/vipulac.in\/\"><strong>Vipul Ac<\/strong><\/a>\u00a0to learn about our HVAC Service<\/p>\n<p style=\"text-align: center;\">Call\u00a0<strong>+91 9825636606<\/strong><span style=\"color: #800000;\">\u00a0<\/span>Today.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Treated fresh air unit calculation (TFA) involves several factors and can be complex. It&#8217;s generally recommended to consult with a qualified HVAC professional to ensure your unit is properly sized and meets your specific needs. However, here&#8217;s a breakdown of the key aspects involved in TFA calculations: 1. Fresh Air Requirement: This is the core [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"footnotes":""},"categories":[206,6,209,2,202,54],"tags":[],"class_list":["post-1839","post","type-post","status-publish","format-standard","hentry","category-ahu","category-home-ac-system","category-hot-and-cold-insulation","category-hvac-system","category-mep-consultant","category-vrf"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Treated fresh air unit calculation - The Complete HVAC Solutions | Call now +91 8000392000<\/title>\n<meta name=\"description\" content=\"Treated fresh air unit calculation (TFA) involves several factors, consult with a qualified HVAC professional to ensure your unit\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/vipulac.in\/blog\/treated-fresh-air-unit-calculation\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Treated fresh air unit calculation - The Complete HVAC Solutions | Call now +91 8000392000\" \/>\n<meta property=\"og:description\" content=\"Treated fresh air unit calculation (TFA) involves several factors, consult with a qualified HVAC professional to ensure your unit\" \/>\n<meta property=\"og:url\" content=\"https:\/\/vipulac.in\/blog\/treated-fresh-air-unit-calculation\/\" \/>\n<meta property=\"og:site_name\" content=\"The Complete HVAC Solutions | Call now +91 8000392000\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/VipulNeverSleep\/\" \/>\n<meta property=\"article:published_time\" content=\"2024-04-26T10:51:38+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-04-26T11:32:12+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2024\/04\/455bmzgo-300x158.png\" \/>\n<meta name=\"author\" content=\"bhaveshk\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@VipulNeverSleep\" \/>\n<meta name=\"twitter:site\" content=\"@VipulNeverSleep\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"bhaveshk\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/treated-fresh-air-unit-calculation\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/treated-fresh-air-unit-calculation\\\/\"},\"author\":{\"name\":\"bhaveshk\",\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/#\\\/schema\\\/person\\\/f81ca3288761d151243f2694fedd3e38\"},\"headline\":\"Treated fresh air unit calculation\",\"datePublished\":\"2024-04-26T10:51:38+00:00\",\"dateModified\":\"2024-04-26T11:32:12+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/treated-fresh-air-unit-calculation\\\/\"},\"wordCount\":593,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/treated-fresh-air-unit-calculation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/455bmzgo-300x158.png\",\"articleSection\":[\"AHU\",\"Home AC System\",\"Hot and Cold Insulation\",\"HVAC System\",\"MEP Consultant\",\"Vrf\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/vipulac.in\\\/blog\\\/treated-fresh-air-unit-calculation\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/treated-fresh-air-unit-calculation\\\/\",\"url\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/treated-fresh-air-unit-calculation\\\/\",\"name\":\"Treated fresh air unit calculation - The Complete HVAC Solutions | Call now +91 8000392000\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/treated-fresh-air-unit-calculation\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/treated-fresh-air-unit-calculation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/455bmzgo-300x158.png\",\"datePublished\":\"2024-04-26T10:51:38+00:00\",\"dateModified\":\"2024-04-26T11:32:12+00:00\",\"description\":\"Treated fresh air unit calculation (TFA) involves several factors, consult with a qualified HVAC professional to ensure your unit\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/treated-fresh-air-unit-calculation\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/vipulac.in\\\/blog\\\/treated-fresh-air-unit-calculation\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/treated-fresh-air-unit-calculation\\\/#primaryimage\",\"url\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/455bmzgo.png\",\"contentUrl\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/455bmzgo.png\",\"width\":1024,\"height\":538,\"caption\":\"AHU dealers\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/treated-fresh-air-unit-calculation\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Treated fresh air unit calculation\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/\",\"name\":\"The Complete HVAC Solutions | Call now +91 8000392000\",\"description\":\"The Complete HVAC &amp; VRF Solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/#organization\",\"name\":\"Vipul AC\",\"alternateName\":\"Vipul HVAC Solution PvT. Ltd.\",\"url\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/cropped-vipul_ac_logo-1.png\",\"contentUrl\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/cropped-vipul_ac_logo-1.png\",\"width\":240,\"height\":72,\"caption\":\"Vipul AC\"},\"image\":{\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/VipulNeverSleep\\\/\",\"https:\\\/\\\/x.com\\\/VipulNeverSleep\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/vipulac\\\/\",\"https:\\\/\\\/www.instagram.com\\\/vipulaircondition\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/#\\\/schema\\\/person\\\/f81ca3288761d151243f2694fedd3e38\",\"name\":\"bhaveshk\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/5a5186bf62b0fb1f890be660179375d8bba84123066154ffb79e5a96bb20c75a?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/5a5186bf62b0fb1f890be660179375d8bba84123066154ffb79e5a96bb20c75a?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/5a5186bf62b0fb1f890be660179375d8bba84123066154ffb79e5a96bb20c75a?s=96&d=mm&r=g\",\"caption\":\"bhaveshk\"},\"sameAs\":[\"https:\\\/\\\/vipulac.in\\\/blog\"],\"url\":\"https:\\\/\\\/vipulac.in\\\/blog\\\/author\\\/bhaveshk\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Treated fresh air unit calculation - The Complete HVAC Solutions | Call now +91 8000392000","description":"Treated fresh air unit calculation (TFA) involves several factors, consult with a qualified HVAC professional to ensure your unit","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/vipulac.in\/blog\/treated-fresh-air-unit-calculation\/","og_locale":"en_US","og_type":"article","og_title":"Treated fresh air unit calculation - The Complete HVAC Solutions | Call now +91 8000392000","og_description":"Treated fresh air unit calculation (TFA) involves several factors, consult with a qualified HVAC professional to ensure your unit","og_url":"https:\/\/vipulac.in\/blog\/treated-fresh-air-unit-calculation\/","og_site_name":"The Complete HVAC Solutions | Call now +91 8000392000","article_publisher":"https:\/\/www.facebook.com\/VipulNeverSleep\/","article_published_time":"2024-04-26T10:51:38+00:00","article_modified_time":"2024-04-26T11:32:12+00:00","og_image":[{"url":"https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2024\/04\/455bmzgo-300x158.png","type":"","width":"","height":""}],"author":"bhaveshk","twitter_card":"summary_large_image","twitter_creator":"@VipulNeverSleep","twitter_site":"@VipulNeverSleep","twitter_misc":{"Written by":"bhaveshk","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/vipulac.in\/blog\/treated-fresh-air-unit-calculation\/#article","isPartOf":{"@id":"https:\/\/vipulac.in\/blog\/treated-fresh-air-unit-calculation\/"},"author":{"name":"bhaveshk","@id":"https:\/\/vipulac.in\/blog\/#\/schema\/person\/f81ca3288761d151243f2694fedd3e38"},"headline":"Treated fresh air unit calculation","datePublished":"2024-04-26T10:51:38+00:00","dateModified":"2024-04-26T11:32:12+00:00","mainEntityOfPage":{"@id":"https:\/\/vipulac.in\/blog\/treated-fresh-air-unit-calculation\/"},"wordCount":593,"commentCount":0,"publisher":{"@id":"https:\/\/vipulac.in\/blog\/#organization"},"image":{"@id":"https:\/\/vipulac.in\/blog\/treated-fresh-air-unit-calculation\/#primaryimage"},"thumbnailUrl":"https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2024\/04\/455bmzgo-300x158.png","articleSection":["AHU","Home AC System","Hot and Cold Insulation","HVAC System","MEP Consultant","Vrf"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/vipulac.in\/blog\/treated-fresh-air-unit-calculation\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/vipulac.in\/blog\/treated-fresh-air-unit-calculation\/","url":"https:\/\/vipulac.in\/blog\/treated-fresh-air-unit-calculation\/","name":"Treated fresh air unit calculation - The Complete HVAC Solutions | Call now +91 8000392000","isPartOf":{"@id":"https:\/\/vipulac.in\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/vipulac.in\/blog\/treated-fresh-air-unit-calculation\/#primaryimage"},"image":{"@id":"https:\/\/vipulac.in\/blog\/treated-fresh-air-unit-calculation\/#primaryimage"},"thumbnailUrl":"https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2024\/04\/455bmzgo-300x158.png","datePublished":"2024-04-26T10:51:38+00:00","dateModified":"2024-04-26T11:32:12+00:00","description":"Treated fresh air unit calculation (TFA) involves several factors, consult with a qualified HVAC professional to ensure your unit","breadcrumb":{"@id":"https:\/\/vipulac.in\/blog\/treated-fresh-air-unit-calculation\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/vipulac.in\/blog\/treated-fresh-air-unit-calculation\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/vipulac.in\/blog\/treated-fresh-air-unit-calculation\/#primaryimage","url":"https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2024\/04\/455bmzgo.png","contentUrl":"https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2024\/04\/455bmzgo.png","width":1024,"height":538,"caption":"AHU dealers"},{"@type":"BreadcrumbList","@id":"https:\/\/vipulac.in\/blog\/treated-fresh-air-unit-calculation\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/vipulac.in\/blog\/"},{"@type":"ListItem","position":2,"name":"Treated fresh air unit calculation"}]},{"@type":"WebSite","@id":"https:\/\/vipulac.in\/blog\/#website","url":"https:\/\/vipulac.in\/blog\/","name":"The Complete HVAC Solutions | Call now +91 8000392000","description":"The Complete HVAC &amp; VRF Solutions","publisher":{"@id":"https:\/\/vipulac.in\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/vipulac.in\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/vipulac.in\/blog\/#organization","name":"Vipul AC","alternateName":"Vipul HVAC Solution PvT. Ltd.","url":"https:\/\/vipulac.in\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/vipulac.in\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2025\/10\/cropped-vipul_ac_logo-1.png","contentUrl":"https:\/\/vipulac.in\/blog\/wp-content\/uploads\/2025\/10\/cropped-vipul_ac_logo-1.png","width":240,"height":72,"caption":"Vipul AC"},"image":{"@id":"https:\/\/vipulac.in\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/VipulNeverSleep\/","https:\/\/x.com\/VipulNeverSleep","https:\/\/www.linkedin.com\/in\/vipulac\/","https:\/\/www.instagram.com\/vipulaircondition\/"]},{"@type":"Person","@id":"https:\/\/vipulac.in\/blog\/#\/schema\/person\/f81ca3288761d151243f2694fedd3e38","name":"bhaveshk","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/5a5186bf62b0fb1f890be660179375d8bba84123066154ffb79e5a96bb20c75a?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/5a5186bf62b0fb1f890be660179375d8bba84123066154ffb79e5a96bb20c75a?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/5a5186bf62b0fb1f890be660179375d8bba84123066154ffb79e5a96bb20c75a?s=96&d=mm&r=g","caption":"bhaveshk"},"sameAs":["https:\/\/vipulac.in\/blog"],"url":"https:\/\/vipulac.in\/blog\/author\/bhaveshk\/"}]}},"_links":{"self":[{"href":"https:\/\/vipulac.in\/blog\/wp-json\/wp\/v2\/posts\/1839","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vipulac.in\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/vipulac.in\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/vipulac.in\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/vipulac.in\/blog\/wp-json\/wp\/v2\/comments?post=1839"}],"version-history":[{"count":4,"href":"https:\/\/vipulac.in\/blog\/wp-json\/wp\/v2\/posts\/1839\/revisions"}],"predecessor-version":[{"id":1859,"href":"https:\/\/vipulac.in\/blog\/wp-json\/wp\/v2\/posts\/1839\/revisions\/1859"}],"wp:attachment":[{"href":"https:\/\/vipulac.in\/blog\/wp-json\/wp\/v2\/media?parent=1839"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/vipulac.in\/blog\/wp-json\/wp\/v2\/categories?post=1839"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/vipulac.in\/blog\/wp-json\/wp\/v2\/tags?post=1839"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}